Top Solo Valve - Removal; Circulation Pump With Top Solo Valve Attached - Miele G600 User Manual

Electronic dishwashers
Table of Contents

Advertisement

Technical Information
5.41

Top Solo Valve - Removal

1. Remove the Circulation Pump (5.35).
2. Disconnect the Electrical Connection.
Warning
It is essential to note correct position of the Valve before removal.
(The direction of flow is marked by an arrow on the Valve Housing)
3. Pull the valve away from the circulation pump.
Figure 5-35: Circulation Pump with Top Solo Valve attached.
Service Tip
During re-installation of the Top Solo Valve ensure the cutout on the
Valve Housing engages with the lug on the Circulation Pump
Housing.