Panasonic UJ30 Series User Manual page 51

Uj30/uj35 series led uv curing system aicure spot type
Table of Contents

Advertisement

4.
Using the operation setting screen
[Settings 1]
1) Set UJ – Selects Type from 0 to 7 (does not switch CH selection).
*During Type selection Type Change is highlighted.
・Read
・Write
・Cancel
2) "Switch Display"... Switches the display mode of the controller.
*Settable only when UJ35 controller is online.
• "% / SEC"
• "TEMP"
• "×100hrs"
3) "INTERLOCK"... Locks and unlocks the UJ35 controller settings.
*Settable only when UJ35 controller is online.
• [INTERLOCK OFF]
• [INTERLOCK ON]
• ON/OFF
Reads the current Type setting from UJ35 controller into computer.
Uploads current Type from computer to UJ35 controller.
Cancels current Type setting operation and return to start.
For display of irradiation intensity and time.
For display of head temperature.
For display of lifetime setting and cumulative irradiation time.
Switches interlock off (state on UJ35 controller side)
Sets interlock ON (highlighted on screen) (state on UJ35 controller side)
Toggles UJ35 controller interlock ON and OFF
External control
41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uj35 seriesAnuj3000Anuj3500Anuj3000-ncAnuj3500-nc

Table of Contents