External control

WRITE procedure

Communication data is accepted at each address, and the accepted data will be confirmed by
the execution of the data setting address and data memory address.
-
Data confirmed by the setting address will be written to memory when the controller is
powered OFF.
Data confirmed by the memory address will be written to memory and be retained even
after the controller is powered OFF.
Note: Memory can be rewritten up to one million times. If you rewrite to memory frequently,
you may only be able to execute data settings, so write only the final data to memory.