5 Receiving IP alarm notification

An IP alarm notification is issued by the recorder when a trigger signal is input to any rear terminal, recording is
started, or any warning occurs. You can receive this notification by a pop-up window displayed on the networked
PC monitor.
It is also possible to access the relevant recorder from this pop-up window.
5.1

Setting for sending notification from the recorder

Register a destination PC that receives notification in the recorder.
In DX-TL2500 series, you can a destination PC using the communication setting screen of the recorder. For the
setting procedure, see the operation manual of the recorder.
In DX-TL5000 series, use this software to set a destination PC. Click the [Load] button in the [Recorder] field on
the recorder setting panel (
Setting].
[Load] button in the
[Recorder] field
The [LAN B Address Setting] dialog box appears. Enter the IP address of the destination PC, sending port number
(receiving port on the PC side), and receiving port number (sending port on the recorder side) in the [IP Alarm
Notification Information] field. Then select the events you want to be informed from six groups and put a
checkmark to them. Use the default port number in normal use. You can enable or disable issuance of notification
to the destination PC using the checkbox at the left.
When you complete entering necessary data, click the [Register] button in the [Recorder] field. The data you
entered take effect in the recorder. Then, stop recording, cancel the menu display on the monitor, and turn off the
power of the recorder. (When the recorder is run by the timer program, turn off the timer program first.) After
registration, use the recorder as before.
5.2

Setting for receiving notification by PC

[To receive notification from DX-TL2500 series]
No special settings are required when you want to display all alarm events by pop-up windows.
However, when you have changed the sending port in 5.1 on page 40 or when you want to limit alarm events
reported by pop-up windows, make necessary settings according to
[To receive notification from DX-TL5000 series]
No settings are required.
However, when you have changed the sending port in 5.1 on page 40, set the receiving port number on the PC
side referring to
4.18.5 on page 39.
see 4.14 on page 32). Select the [COM/LAN] tab and click [LAN B Address
– 40 –
[COM/LAN] tab
[LAN B Address Setting]
4.18.5 on page 39.