NEC Storage Manager Messages Handbook page 191

Messages handbook
Table of Contents

Advertisement

Chapter 2 Message List
iSM10308: command: <aaa...a>, mv=<bbb...b>
[Classification]
[Explanation]
[Measures]
iSM10309: command: <aaa...a>, mv=<bbb...b>
[Classification]
[Explanation]
[Measures]
(<cccc>h) <ddd...d>, rv=<bbb...b>
(<cccc>h) <ddd...d>, status=failed
(<ee>h/<ff>h/<gg>h)
INFO
It indicates that it failed in accessing the pair expressed in MV or RV (failure of
SCSI protocol).
aaa...a
: Command name
bbb...b
: Logical disk name
cccc
: Volume number
ddd...d
: Disk array name
ee
: Sense Key defined in SCSI specification
ff
: Additional Sense Code defined in SCSI specification
gg
: Additional Sense Code Qualifier defined in SCSI specification
As for command name, refer to the "NEC Storage Manager Data Replication
User's Manual (Function Guide)".
Check whether the configuration of disk array has been changed.
(<cccc>h) <ddd...d>, rv=<bbb...b>
(<cccc>h) <ddd...d>, status=failed
(ec=<eee...e>)
INFO
It indicates that it failed in accessing the pair expressed in MV or RV (failure
except for SCSI protocol).
aaa...a
: Command name
bbb...b
: Logical disk name
cccc
: Volume number
ddd...d
: Disk array name
eee...e
: Error code
As for command name, refer to the "NEC Storage Manager Data Replication
User's Manual (Function Guide)".
Check whether the configuration of disk array has been changed.
186