iSM09014: Failed in termination of LD movement
from <aaaa>(<bbb...b>) to
<cccc>(<ddd...d>) in <eee...e>
detcode=<ffffffff>
[Classification]
NOTICE
[Explanation]
It indicates that the attempt to terminate the logical disk movement process
failed.
aaaa
bbb...b
cccc
ddd...d
eee...e
ffffffff
[Measures]
Find the cause of the error on the disk array based on the information shown in
other message, remove the cause and resume monitoring. When monitoring is
resumed, the termination process for the logical disk movement is executed
again.
iSM09015: Illegal LD movement information was
received from <aaa...a>
[Classification]
NOTICE
[Explanation]
It indicates that the following abnormality occurred in moving of logical disks.
(1) The movement information of the logical disk included illegal information.
(2) Issuing of requests regarding moving logical disks failed.
aaa...a
[Measures]
Take the measures below.
(1) Collect information necessary for checking the error cause according to the
(2) Find the cause of the error on the disk array based on the information shown
: Logical disk number of moved material logical disk
: Logical disk name of moved material logical disk
: Logical disk number of work disk for Optimization
: Logical disk name of work disk for Optimization
: Disk array name
: Detail code
: Disk array name
iSM error information collection procedure.
in other message, remove the cause and resume monitoring.