TeamPoS 3000 XL and XL
4.8
Installation with Other Equipment
In most cases, dedicated AC mains circuits are not required for the TeamPoS
3000XL and XL
power with the terminal may cause adverse effects on the terminal. When this
occurs, electrical isolation may be required and is the responsibility of the
customer or installing contractor.
Terminals at 100-240 volts
The table below details the power requirements for the TeamPoS series control
unit. Provide 100-240 volts AC, 50/60 Hz, single phase, with the following
amperage requirements:
Property
Grounding
Power system
Rated voltage and frequency
Rated current
Operational frequency limits
Earth leakage current
Power dissipation
Maximum HRC fuse rating for
external short-circuit protection
Main power cord:
Length
Diameter
Minimum bend radius
D900000145
2
2
terminals. In rare instances, other electrical equipment sharing
Value or Description
The terminals are Class 1 equipment and must be
supplied via a socket-outlet which has a protective
ground contact connected to the protective ground of the
terminal.
The terminals are designed for use on a power system
with a grounded neutral, i.e., a TN or TT power system.
The terminals must not be directly connected to a power
system with impedance grounded neutral, i.e., an IT
power system.
100 - 240 volts, 50/60 Hz
1.8 A / 3.6 A
47 – 63 Hz
< 1.0 mA
250 watts
10 A / 20 A
3.00 m (9.80 ft.)
8.0 mm (0.30 in.)
10.0 mm (0.40 in.)
Issue 3
Site Preparation
4-6