TeamPoS 3000 XT
4.8.

Installation with Other Equipment

In most cases, dedicated AC mains circuits are not required for the TeamPoS
3000 XT terminals. In rare instances, other electrical equipment sharing power
with the terminal may cause adverse effects on the terminal. When this occurs,
electrical isolation may be required and is the responsibility of the customer or
installing contractor.
4.8.1.

Terminals at 100-240 Volts

Table 4-1 details the power requirements for the TeamPoS 3000 XT control unit.
Property
Grounding
Power system
Rated voltage and frequency
Rated current
Operational frequency limits
Earth leakage current
Power dissipation
Maximum HARK fuse rating
for external short-circuit
protection
Main power cord:
Length
Diameter
Minimum bend radius
4-6
Table 4-1. Power Requirements
Value or Description
The terminals are Class 1 equipment and must be
supplied via a socket outlet with a protective ground
contact connected to the protective ground of the
terminal.
The terminals are designed for use on a power system
with a grounded neutral; i.e., a TN or TTS power system.
The terminals must not be directly connected to a power
system with an impedance-grounded neutral; i.e., an IT
power system.
100 - 240 volts, 50/60 Hz
3.6 A
47 – 63 Hz
< 1.0 am
250 watts
20 A
3.00 m (9.80 ft.)
8.0 mm (0.30 in.)
10.0 mm (0.40 in.)
Installation and Maintenance Manual
D900000172