Hardware Monitoring Setup -Motherboard - Fujitsu TeamPoS 3000 XL Installation & Maintenance Manual

Table of Contents

Advertisement

TeamPos 3000 XL and XL
9.1.16 Hardware Monitoring Setup - Motherboard
Factory Default Settings
Hardware Monitoring
CPU Temperature
CPU Temp Warning Action
CPU Temp for Warning
PSU Temperature
PSU Temp Warning Action
PSU Temp for Warning
System Temperature
System Temp Warning Action
System Temp for Warning
Low temperature
x Temperature
CPU Fan Speed
CPU Fan Control
CPU Temp to up CPU Fan
SYS Temp to up CPU Fan
CPU Fan Warning
x CPU Fan Warning Speed
PSU Fan Speed
PSU Fan Control
CPU Temp to up PSU Fan
SYS Temp to up PSU Fan
PSU Temp to up PSU Fan
PSU Fan Warning
PSU Fan Warning Speed
 Voltage Monitoring Group
    : Move
Enter : Select
F5: Previous Values
* All actual temperatures and fan speeds will vary.
** Note: CPU fan control and warning must be [DISABLED] since there is no fan on
CPU.
D900000145
2
Phoenix – AwardBIOS CMOS Setup Utility
Hardware Monitoring
[Enabled]
36° C
[Shutdown]
[90°C/194°F]
28° C
[Shutdown]
[70°C/158°F]
20° C
[Disabled]
[65°C/149°F]
[Disabled]
5°C/41°F
0 RPM
[Disabled]
[80°C/176°F]
[45°C/113°F]
[Disabled]
4000 RPM
2934 RPM
[POS]
[80°C/176°F]
[45°C/113°F]
[55°C/131°F]
[Shutdown]
[2000RPM]
[Press Enter]
+/-/PU/PD : Value
F7: Optimized Defaults
Issue 3
BIOS XL Motherboard
Item Help
Menu Level 
Information or instructions
will appear here for each
selection.
F10 : Save
ESC : Exit
F1: General Help
9-14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Teampos 3000 xl2

Table of Contents