NorthStar EXPLORER AP380 Installation And Operation Manual page 15

Hide thumbs Also See for EXPLORER AP380:
Table of Contents

Advertisement

Installing a electric drive motor with clutch relay
In the Setup > Vessel menu (See Explorer AP380 system Operation Section), set Drive Type to Motor.
Heavy duty power (see section 3-4-1)
1N4002 diode or equivalent
Fit close to relay coil
Installing a continuous running pump and solenoid valves.
In the Setup > Vessel menu (See Explorer AP380 system Operation Section), set Drive Type to Spool ground.
Heavy duty power (see section 3-4-1)
Note: Motor is not
required for engine
PTO systems.
Fit strain relief
Relay contacts
Clutch
coil
Wiring polarity does
not matter.
Motor
Fit strain relief
Relay contacts
Motor
Wiring polarity does
Starboard
Port
Northstar Explorer AP380 System Installation and Operation Manual
MCU600
1N4002 diode or equivalent. Fit
close to relay coil
Note: Relay is required if the clutch circuit
is greater than 300 mA.
MCU600
not matter.
Connector cover
Relay coil
Connector cover
Relay coil
1N4002 diode or equivalent
Fit close to relay coil
Note: Relay is required if the
clutch circuit is greater than
300 mA.
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents