Mitsubishi Electric 800 Series Instruction Manual page 35

Vector control terminal block
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

NOTE
• For the connection to the terminal 5, use a screwdriver with a diameter of 1.6 mm or less. Put the screwdriver to avoid
contact with the mounting screw area.
φ
1.6 mm or less
• When one position detector is shared between the FR-A8TP and the CNC (computerized numerical controller), its output
signal should be connected as shown below. In this case, the wiring length between the FR-A8AP and the CNC should be
as short as possible, within 5 m.
34
WIRING
Inverter
Position detector
(FR-A8TP)
Maximum 5 m
(Two parallel cables)
Encoder
NC
Avoid contact with
mounting screw area