Mitsubishi Electric MELIPM Series Instruction Manual page 72

Magnetic motor drive unit
Table of Contents

Advertisement

iii) Parameter write and read
Parameter write and read require the setting of the extension codes given in
Appendix 1 Parameter List (Numerical Order). After setting the extension
code, set the instruction code given in Appendix 1 Parameter List
(Numerical Order) and perform write or read.
This function is performed as set in Pr. 77.
Setting Item
Mode
Write
Extension
code setting
Read
Write
Parameter
Read
Once written, the setting of the HFF instruction code is held, but is
MEMO
cleared to "0" when the drive unit is reset or all clear is performed.
When converting a value having a decimal place, e.g. parameter setting range,
into a data code, make conversion in the setting range whose decimal place has
been carried. Use "HFFFF" with the value "9999" which means no function.
(Example)
Setting Range
Parameter
(Parameter list)
Pr. 7
0.0 to 60
0 to 7200
Pr. 24
9999
0
Pr. 122
0.1 to 999.8
9999
0
Pr. 124
1
2
Instruction
Data Codes and Definitions
Code
H00: Parameter of extension code 0
can be accessed for read/write.
HFF
H01: Parameter of extension code 1
can be accessed for read/write.
H02: Parameter of extension code 2
can be accessed for read/write.
H7F
H09: Parameter of extension code 9
can be accessed for read/write.
Refer to
Appendix 1
H0000 to HFFFF: Parameter settings
Parameter
(hexadecimal)
List.
Setting Range
(Communication)
0 to 6000
0 to 7200
9999
0
1 to 9998
9999
0
1
2
8-18
Get other manuals https://www.bkmanuals.com
8 PARAMETER FUNCTIONS
Character
Data Code
H0000 to H1770
H0000 to H1C20
HFFFF
H0000
H0001 to H270E
HFFFF
H0001
H0002
H0003
count
2
4

Advertisement

Table of Contents
loading

Table of Contents