Common Specifications - Mitsubishi Electric MELIPM Series Instruction Manual

Magnetic motor drive unit
Table of Contents

Advertisement

7.1.2 Common specifications

(1) Control specifications
Control system
Carrier frequency
Max. output speed
Analog input
Speed setting
resolution
Digital input
Speed output resolution
Analog input
Speed
accuracy
Digital input
Starting torque
Speed control range
Initial magnetic pole
detection time
Acceleration/deceleration
time setting range
Stall prevention operation
level
Sensor-less PWM control
7200r/min (output frequency 240Hz)
1/1000 of the max. preset speed
1/500 when 5VDC is selected
Within ±0.5% of maximum output speed
Within ±0.05% of maximum output speed
Approx. 0.1s (85ms±15ms)
(acceleration and deceleration can be set individually)
Operation level can be set (60 to 200%), presence or
absence can be selected.
7-2
Get other manuals https://www.bkmanuals.com
7. SPECIFICATIONS
7.5kHz fixed
1r/min
0.3r/min
120% or more
1 : 10
0.5 to 60.0s

Advertisement