Mitsubishi Electric MELIPM Series Instruction Manual page 61

Magnetic motor drive unit
Table of Contents

Advertisement

Pr. 31 to 36 "speed command jumps 1A to 3B"
Pr.
31 to 36
You can set three speed areas where continuous operation will be disabled. You
can avoid continuous operation at the speed at which resonance will occur due to
the natural frequency of a mechanical system. When the speed command within
the setting range is input, continuous operation is performed at the preset speed
of value A.
Setting "9999" in the parameter makes this function invalid.
The "speed command jump" function is designed to disable
continuous operation between the preset A and B points. When the
running speed command is outside A-B, the speed varies between
MEMO
A and B in accordance with the preset acceleration/deceleration
time.
Any setting less than 300r/min will be a stop (0r/min) setting.
Pr. 78
"reverse rotation prevention selection"
You can fix the direction of rotation.
Setting
Forward or reverse rotation operation is performed in accordance with the
0
forward or reverse rotation command.
Forward rotation operation is performed in accordance with the forward
1
rotation command. Operation is stopped in response to the reverse rotation
command.
Reverse rotation operation is performed in accordance with the reverse
2
rotation command. Operation is stopped in response to the forward rotation
command.
Setting Range
0 to 7200, 9999
Speed jump
Pr.36(3B)
Pr.35(3A)
Pr.34(2B)
Pr.33(2A)
Pr.32(1B)
Pr.31(1A)
8-7