Figure 3-2 Fusion System Configuration With Fch - NEC NEAX 2400 IMX Manual

Fusion network system
Hide thumbs Also See for NEAX 2400 IMX:
Table of Contents

Advertisement

SYSTEM CONFIGURATION
Fusion System with FCH
2. Fusion System with FCH
2.1 System Configuration
A sample Fusion system configuration that uses a DTI to carry D-channel is shown below. In this configu-
ration, the Fusion link is established between nodes via the T1 link.
figuration with FCH.
This figure shows a Fusion System Configuration with FCH.
Node A
TSW/INT
MUX
CPU
PCI Bus
TSW (Time Division Switch): PH-SW 10
HUB: PA-M96
MUX: PH-PC36
LANI (LAN Interface): PZ-PC19
FCH (Fusion Call Control Handler): PA-FCHA
DTI (Digital Trunk Interface): PA-24DTR
2.2 Redundancy of Fusion Link
The FCH (PA-FCHA) card handles a Fusion link, occupying one time slot of a frame by D/I function located
on the DTI card. In terms of redundancy, the Fusion system (with FCH) can have one of the following config-
urations.
Redundant Configuration (LANI, HUB, FCH, and DTI)
Redundant Configuration (HUB, FCH, and DTI)
Redundant Configuration (FCH and DTI)
Non-Redundant Configuration
CHAPTER 3
Page 12
Revision 3.0
D-channel (example)
ch 0
Fusion Link
DTI
B-channel / D-channel
D/I
FCH
10 Base T
FCH
......
HUB
10 Base T
LANI

Figure 3-2 Fusion System Configuration with FCH

ND-70185 (E)
Get other manuals https://www.bkmanuals.com
Figure 3-2
shows a Fusion system con-
ch 23
MUX
DTI
D/I
FCH
10 Base T
FCH
. . .
. . .
HUB
10 Base T
LANI
PCI Bus
Node B
TSW/INT
CPU