Figure 5-33 Afpc Sample Data Sheet - NEC NEAX 2400 IMX Manual

Fusion network system
Hide thumbs Also See for NEAX 2400 IMX:
Table of Contents

Advertisement

The table in
Figure 5-33
shows a sample data sheet for Node A on a Fusion network with FCH. Assign the data
for all nodes including the nodes which are not directly connected on the network. For example, in this figure
Node C and Node D are not directly connected to the network.
AFPC (at Node A) - Fusion with FCH
Node B
FPC 2(to Node B) FCCH 1(with FCH)
CNT
1
Node C
FPC 21(to Node C) FCCH 1(with FCH)
CNT
1
Assign all nodes' data in the same manner.
This table shows a sample data sheet for Node A on the fusion network without FCH. Assign the data for all nodes including
the nodes which are not directly connected on the network. (i.e.Node C, Node D.....)
AFPC (at Node A) - Fusion without FCH
Node B
FPC 2(to Node B) FCCH 0(without FCH )
CNT
1
Assign adjacent Node's FPC
Node C
FPC 21 (to Node C) FCH 0 (without FCH0)
CNT
1
Assign adjacent Node's FPC
Assign all nodes' data in the same manner.
C_RT
FCHN
10
1
C_RT
FCHN
10
1
C_RT
FPCN
10
2
Assign destination (far end) Node's FPC
C_RT
FPCN
10
2

Figure 5-33 AFPC Sample Data Sheet

ND-70185 (E)
Get other manuals https://www.bkmanuals.com
Assignment of FCH Related Data
-To Node B-
Node A
1
C_RT=10
FCHN=1
-To Node C-
Node A
1
C_RT=10
FCHN=1
-To Node B-
Node A
1
C_RT=10
FCHN=1
-To Node C-
Node A
1
C_RT=10
FCHN=1
DATA PROGRAMMING
Node B
2
Node C
21
Node B
2
Node B
2
Node C
21
Node B
2
CHAPTER 5
Page 85
Revision 3.0

Advertisement

Table of Contents
loading