I Specifications of Setup Switches

20
Label
Interface
marking
ALM1
OUT
GND
RLT2
OUT
GND
BUZZ
IN
GND
SYNC
IN
GND
ON
1
2
3
I/O
Signal Description
This terminal is closed
and low when power is
supplied from an external
power-supply device to
the iris reader.
The terminal is opened
when the power supply is
shut down.
This terminal is activated
when recognition is not
successfully completed.
An alarm signal is input to
this terminal to activate
buzzer sound.
An external master clock
is connected.
Refer to the dealer for
available external
devices.
4
5
6
7
8
Remarks
24 V DC, 24 mA (Max)
Open collector output
Normally Close contact
(Low level)
24 V DC, 24 mA (Max)
Open collector output
Normally Open contact
Active low, Pulse width:
0.1 s to 60 s
0 V to 5 V DC, 24 mA
(Max), Active low,
Pulse width: 200 ms or
more
0 V to 5 V DC, 24 mA
(Max), Active low,
Pulse width: 100 ms or
more