Panasonic DBS Series Programming Manual page 57

Digital business system
Hide thumbs Also See for DBS Series:
Table of Contents

Advertisement

Panasonic Digital Business System - Programming Manual
April 1997
Number Of DDI Digits Used
The E-ISDN protocol does not delimit the DDI field like DASSII, therefore the system must be set
to extract the correct number of digits from the D channel information accompanying the incoming
call before the digits can be used to route internally.
DDI Operator Call Overflow
The number of simultaneous ringing incoming DDI calls to the operator extension can be limited to
between 1 and 15, If set, further calls will be routed to the specified overflow extension or group as
set in FF6 4# 23#. This setting operates in a similar manner to Operator Call Overflow FF1 2# 1#
15#, but the steps are not linked together and each operates independently of the other.
Related Step:
FF1 6# 4# 23# - Extension for DDI Operator Overflow
Extension For DDI Operator Call Overflow
This step specifies the extension number or group ( using a virtual extension number ) to receive
incoming DDI calls which overflow from the operator extension.
Related Steps: FF1 6# 4# 22# - DDI Operator Overflow
FF4 8# - Assignment Of Extension Numbers To Groups
FF1 6# 4# 21# (1-6)#
(1-6)# Number Of DDI Digits Used
4# 4 DDI Digits
FF1 6# 4# 22# (0-15)#
0# No Overflow
1#
Overflow after 1 DDI call
2#
Overflow after 2 DDI calls
3#
Overflow after 3 DDI calls
4#
Overflow after 4 DDI calls
5#
Overflow after 5 DDI calls
6#
Overflow after 6 DDI calls
7#
Overflow after 7 DDI calls
8#
Overflow after 8 DDI calls
9#
Overflow after 9 DDI calls
10#
Overflow after 10 DDI calls
11#
Overflow after 11 DDI calls
12#
Overflow after 12 DDI calls
13#
Overflow after 13 DDI calls
14#
Overflow after 14 DDI calls
15#
Overflow after 15 DDI calls
FF1 6# 4# 23# (NNNN)#
CONF#
Clear
NNNN# Extension or Group Virtual Extension Number
57
Issue 15
CPC-EX v1.5
CPC-EX v2.1
CPC-EX v2.1

Advertisement

Table of Contents
loading

Table of Contents