7. TROUBLE SHOOTING
Symptom
Inspection
The unit is not
Check the mains supply
working
Check if the water level indicator lights
up?
Check the room temperature.
The unit works with
Check if the air duct is blocked
reduced capacity
Check the air filter for dirt
Check if the room door or window is open.
Check if the desired operating mode is
selected and temperature is properly set.
The exhaust hose is detached.
Water Leakage
Overflow while moving the unit.
Check if the drain hose is kinked or bent.
Excessive Noise
Check if the unit is securely positioned.
Check if any loose, vibrating parts.
Noise sounds like water flowing.
Error
E0
Communication faults between main PCB
Codes
and display PCB.
E1
Ambient temperature sensor failure
E2
Coil temperature sensor failures.
Ft
Condensate water high level alarm.
WINDOW SEALING KIT FOR AIR CONDITIONER DUCTING
MODEL NO:
8. SAFETY
DO NOT cover the unit with this material, and do not obstruct the air inlet and outlet grilles of the machine with items such as
8
clothing,soft furnishings, furniture, bedding etc.
DO NOT use the material for any purpose other than that for which it is designed.
8
DO NOT use in bathroom or shower room.
8
DO NOT allow children to use, when not in use,store in a safe, cool, dry, childproof area.
8
NOTE: This material is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or
lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they do not play with this material.
9. INTRODUCTION
Suitable for all types of hinged windows including skylights up to 300cm total perimeter. Easy to install using the supplied roll of self-
adhesive hook & loop tape. Double zip makes positioning the ducting at any height easy. Saves energy by making the air conditioner
or dryer more effective.
10. CONTENTS
Window seal
Velcro tape
© Jack Sealey Limited
SACWK1
Window seal with zip
Original Language Version
Solution
Insert the power cord securely into the wall outlet
Empty the drain pan. See Section 5.5
The range of operating temperature is 5-35
Clear the obstacle.
Clean the air filter. See Section 7
Keep the door and windows closed.
Set the mode and temperature at proper set-point
See Section 5
Make sure the exhaust hose is securely attached.
Empty the water tank before transport.
Straighten the hose to avoid a trap existing.
Place the unit on horizontal and firm ground.
Secure and tighten the parts.
Noise comes from flowing refrigerant. This is normal.
Check the wire harness of the display PCB for damage.
Check connection or replace it. To clean or replace the
temperature sensor.
Check connection or replace it. To clean or replace the
temperature sensor.
Empty the drain pan. See Section 5.5