Download Print this page
Sealey SAC12000.V3 Quick Start Manual

Sealey SAC12000.V3 Quick Start Manual

Air conditioner/dehumidifier/heater

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Do not cover
Indoor use only
instruction
manual
1. SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the user's responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all
electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical
products. You may obtain an RCD by contacting your local Sealey dealer.
If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance
Test) tested.
Electrical safety information: it is important that the following information is read and understood.
1.1.1.
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.1.2.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
IMPORTANT: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the
1.1.3.
correct fuse - see fuse rating in these instructions.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or
8
replaced immediately by a qualified electrician.
1.1.4.
This product is fitted with a BS1363/A 13 Amp 3 pin plug.
If the cable or plug is damaged during use, switch the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.
A) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
B) Connect the BROWN live wire to the live terminal 'L'.
C) Connect the BLUE neutral wire to the neutral terminal 'N'.
Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.1.5.
Products which require more than 13 amps are supplied without a plug. Contact a qualified electrician to ensure that a suitably rated
supply is available. Ensure that an industrial round pin plug and socket are fitted by a qualified electrician.
1.1.6.
If an extension cable reel is used, ensure that it is fully unwound before connection. Use a reel that includes an RCD, an appliance
will be protected by the RCD. The cable core section is important and should be at least 1.5mm
appropriate for this product. We recommend the use of 2.5mm² core section cable.
1.2.
GENERAL SAFETY
Check that the unit is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
9
Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
NOTE: Appliance is filled with R290.
Appliance shall be installed, operated and stored in a room with a floor area larger than 14.4m².
9
DO NOT perforate any of the components in the refrigerant circuit. Refrigerant gas may be odourless.
8
DO NOT attempt any repairs / maintenance unless suitably qualified.
8
DO NOT stand or place any object closer than 500mm from the unit.
8
DO NOT obstruct the air intakes or outlets of the unit, and DO NOT cover with washed clothes.
8
DO NOT place any object into the outlets - the unit has a fan running at high speed, contact with this will cause injury.
8
DO NOT operate the unit when you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT switch the unit off by disconnecting it from the mains. ALWAYS switch to the "OFF" position first.
8
DO NOT remove the float lever from the water collection tank.
8
DO NOT connect or disconnect the plug from the mains with wet hands.
8
Always discard the water from the collection tank, DO NOT use it for any other purpose.
9
Place the unit on a level and stable surface.
9
To prevent water from freezing, DO NOT use the unit at ambient temperatures below 0°C.
9
DO NOT use the unit outside.
8
Ensure that heating appliances are not exposed to the flow of air from the unit.
9
Before attempting to move the unit, empty the contents of the water tank. Use side carrying handles when moving unit.
9
Switch off and disconnect unit from the mains before attempting any cleaning or other maintenance work.
9
Ensure that the unit is turned off correctly when not in use, and stored in a safe, dry area, out of reach of children.
9
© Jack Sealey Limited
Get In Touch
Call: 0845 6880112
Email: info@adremit.co.uk
AIR CONDITIONER/DEHUMIDIFIER/HEATER
SAC12000.V3
MODEL NO:
Caution:
Risk of fire
Original Language Version
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Replacement fuse
13A
rating:
. Ensure that the cable of the reel is
2
SAC12000.V3 Issue 1 11/03/20

Advertisement

loading

Summary of Contents for Sealey SAC12000.V3

  • Page 1 SAC12000.V3 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Specification

    28.8L/day. Refrigerant is R290 300g. Mounted on castors for manoeuvrability. Cable storage keeps unit tidy when not in use. 3. SPECIFICATION MODEL NO: ........... SAC12000.V3 Cooling Capacity: ..........12000Btu/hr Discharge Side Pressure: ..........2.8MPa Energy Class:........A (Cooling) A+ (Heating) IP rating ................IP20...
  • Page 3: Operation

    NOTE: Water will still collect in the drain tank even when the unit is in the heating mode; check the tank and drain regularly. fig.7 5.5. LED DISPLAY GUIDE. 5.5.1. Air Con. mode (fig.8). fig.8 SAC12000.V3 Issue 1 11/03/20 Original Language Version © Jack Sealey Limited Get In Touch Our Address Call: 0845 6880112 Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH Email: info@adremit.co.uk...
  • Page 4: General Maintenance

    Original Language Version © Jack Sealey Limited SAC12000.V3 Issue 1 11/03/20 Get In Touch Our Address Call: 0845 6880112 Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH Email: info@adremit.co.uk...
  • Page 5: Battery Removal

    BATTERY REMOVAL Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.