8. TROUBLE SHOOTING
Symptom
Inspection
The unit is not
Check the mains supply
working
Check if the water level indicator lights
up?
Check the room temperature.
The unit works with
Check if the air duct is blocked
reduced capacity
Check the air filter for dirt
Check if the room door or window is open.
Check if the desired operating mode is
selected and temperature is properly set.
The exhaust hose is detached.
Water Leakage
Overflow while moving the unit.
Check if the drain hose is kinked or bent.
Excessive Noise
Check if the unit is securely positioned.
Check if any loose, vibrating parts.
Noise sounds like water flowing.
Communication faults between main PCB
Error
E0
and display PCB.
Codes
E1
Ambient temperature sensor failure
E2
Coil temperature sensor failures.
Ft
Condensate water high level alarm.
BATTERY REMOVAL
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products
containing batteries (as defined within these regulations), that they are registered with Valpak's registered compliance scheme. Jack
Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call
our technical team on technical@sealey.co.uk or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
Solution
Insert the power cord securely into the wall outlet
Empty the drain pan. See Section 5.10
The range of operating temperature is 5-35
Clear the obstacle.
Clean the air filter. See Section 7
Keep the door and windows closed.
Set the mode and temperature at proper set-point
See Section 5
Make sure the exhaust hose is securely attached.
Empty the water tank before transport.
Straighten the hose to avoid a trap existing.
Place the unit on horizontal and firm ground.
Secure and tighten the parts.
Noise comes from flowing refrigerant. This is normal.
Check the wire harness of the display PCB for damage.
Check connection or replace it. To clean or replace the
temperature sensor.
Check connection or replace it. To clean or replace the
temperature sensor.
Empty the drain pan. See Section 5.10