6.6 Troubleshooting

Troubleshooting
.
Find any failure from
the column below.
.
Follow along the line
to
the
right
where
marked with "○" and
then follow upward to
find suspected cause
and action to be taken
described in the upper
columns.
Image quality
The screen rotates, missing sync.
Too narrow screen width
Too wide screen width
Too small screen height
Too large screen height
The screen is not at the center.
Ditto
The screen is too dark.
The screen is too bright.
White balance is bad.
Any of 3 color beams is missing.
Color purity of white is bad.
Image is not sharp (bad focusing).
No image appears.
Overshoot and smear appear.
Noise on the screen.
The power indicator does not light.
Color varies if brightness varies
Arc in CRT
Protection and
Installation
adjustment function
Refer to description in each column
WIDTH 1, 2 VR (VR101, 102)
WIDTH 1, 2 VR (VR101, 102)
HEIGHT VR (VR18~21)
HEIGHT VR (VR18~21)
H-PHASE VR (VR14~17)
V-CENTER VR (VR10~13)
Adjust white balance.
Adjust white balance.
Degauss switch
Adjust focusing.
Adjust contrast and brightness.
Adjust white balance.
Internal adjustment
Adjustment is not correct.
to retry adjustment.
Failure
6 - 16
L1E-EA0229