12.9

Design

Sensor design
Table 12- 20 Sensor design
Description
Dimension and weight
Process connectors
Electrical connection
Material
Measuring tube design
Measuring tube surface roughness
Self-draining design
SITRANS FC430 with HART
Operating Instructions, 03/2012, A5E03361511-01
Measuring tubes
Process connectors
Sensor enclosure
DSL enclosure
Specification
See "Dimensions and weight" (Page 183)
EN1092-1 B1, PN40, PN100
ISO 228-1 G
ASME B1 20.1 NPT
ASME B16.5-2009, Cl 150, Cl 600
DIN 11851
DIN 32676
DIN 11864-1, DIN 11864-2
ISO 2852
ISO 2853
M12 connector with 4-wire cable
Standard cable with polymer / brass /
stainless steel cable glands
Metric or NPT conduit entries
AISI 316L / W1.4435
Standard: AISI 316L / W1.4435
Hygienic: AISI 316L / W1.4435
AISI 304 / W1.4301
Aluminum with corrosion-resistant coating
Split flow through 2 parallel tubes with combined
cross-section area 50% of the nominal pipe
The measuring tubes are bent in a trapezoidal
curve
Standard: 1.6 µm
Hygienic: 0.8 μm
Yes
Technical data