Advertisement

Functions
8.8 Dosing
2. Individual recipe(s) in menus 2.5.4 to 2.5.8 as required
3. Output(s) in menu 2.4 "Inputs/Outputs" (see table below).
4. Input for dosing control in menu 2.4 "Inputs/Outputs"
8.8.1

Valve control configuration

Valve control dosing
Dosing is controlled with either one or two discrete valves or a single analog valve. The
transmitter provides up to three input/output channels which can be used for dosing control.
The selection of channels is fixed when ordering the system. The channels can be setup for
dosing functionality in parameter 2.5.1 "Dosing Mode" as shown in the table below.
Allocation of the output to a specific dosing sequence element is performed in the software
configuration as follows:
One stage dosing
Configuration of one valve (primary valve).
One of the following channels must be assigned to control the discrete primary valve.
Table 8- 1
One Stage Dosing
Valve control
Channel HW
configuration
Discrete valve
Signal output
control - Primary
Valve
Relay output
130
– Select valve control functionality at parameter "Dosing Mode"
– Select measured process value for dosing at parameter "Process Values"
– Setup dosing name, amount, unit and compensation
– Select valve control sequence
– Select fault handling configuration
Output
channel
2
3
4
3
4
Channel SW configuration
Menu item
2.4.2.1
"Operating Mode"
2.4.2.26
"Status Mode"
2.4.3.1
"Operating Mode"
2.4.3.28
"Status Mode"
2.4.6.1
"Operating Mode"
2.4.6.26
"Status Mode"
2.4.4.1
"Status Mode"
2.4.7.2
"Status Mode"
Value
Status Output
Primary Valve Dosing
Status Output
Primary Valve Dosing
Status Output
Primary Valve Dosing
Primary Valve Dosing
Primary Valve Dosing
SITRANS FC430 with HART
Operating Instructions, 03/2012, A5E03361511-01