Item
REM1000
Fault
REM1000
Error Code
REM1000
Switch
Status
APEX Backup
Port
APEX RF Port
Failure
Configuration • QAM RF Redundancy Configuration
APEX1000 All-Purpose Edge QAM Software Version 2.4.x • Installation and Operation Manual
573408-001-a
Definition/Range
Indicates an REM1000 fault.
Major error code received from the REM; it is reporting a switch status different from
the commanded configuration, or an APEX ID status different from the commanded
configuration.
Error status of the REM1000. Valid only when RF Redundancy Configuration Connection
is other than None.
Depending on the current status, one of the following values will display:
OK – No problems switching, parsing switch_port() message, or with HW.
Invalid Parameter – Invalid value in prior switch_port() msg.
Switch Error – Error switching in response to valid switch_port() msg.
Hardware Error (minor) – Error noted, but the REM can still switch.
APEX ID Conflict (major) – Switch_port() messages with the same apex_id have
been received from multiple APEXs. Switch reset to pass-through configuration.
Hardware Error (major) – REM failure. Switch reset to pass-through configuration.
Displays the Status of the REM1000 switches. Valid only when RF Redundancy
Configuration Connection is other than None.
Depending on the current status, one of the following values will display:
Not Switching – REM1000 is passing inputs 1 – 5 straight through to outputs 1 – 5.
Switching Port X – Where X is 1 to 5. The REM1000 is switching the backup input
port to output port X, and is passing all other input ports to the corresponding output
port.
Displays the State of the configured backup port.
Disabled – QAM RF Redundancy is disabled.
Standby – QAM RF Redundancy is enabled, but the backup is inactive. No failure has
occurred.
Active – Failover has occurred and the backup is active.
Failed – The backup port has failed, and the APEX cannot provide RF redundancy.
Removed – The QAM Module with backup port has been removed. The APEX cannot
provide RF redundancy.
Indicates which port (1 – 5) has failed over to the backup port:
Range: None (0), 1, 2, 3, 4, 5
A zero indicates that the backup port is not active.
Redundancy Status
B