5-2 Setting ⑥ Select Control mode

5-2-6 Select Control mode

【 Input 】
【 Output 】
Command Parameter
CR
Result Parameter
DT
**
CR
**
[initial]
Factory setting mode
* CIS starts by register data of Factory
setting memory.
[mode]
Factory setting
User setting mode1
User setting mode2
User setting mode3
[Operation]
1) boot data :
A setting data of 4 mode in Flash memory copy to
ASIC and FPGA registers .
2) Store data :
All register data of FPGA and ASIC copy to a
designated area (Factory , user setting1 ,2 and 3 ) of
flash memory .
Example
Copy user setting1 data to ASIC and FPGA registers
DT 01 <CR>
TM-XG537C
CR
**
CR
00 01 <CR>
COPYRIGHT © 2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
【 Select Control mode 】
[Function]
select the function mode of CIS .
CIS start to function on Factory setting mode just after
turning on Power .
If it is necessary for CIS to function on a different
parameter which stored user memory area , use this
command and switch a mode.
It is possible to store 3 deferent data each to 3 areas of a
Flash memory . By using this command user setting data
can be stored in a user setting area of a Flash memory .
【 Remarks 】
1) User setting mode can only use after preparing user
setting data and storing them in a user setting area of a
Flash memory . There is no user setting data in CIS
which is just shipped from the factory .
2) Refer the function specification about how to prepare
user setting data .