4-3 Line Sync. Timing ( External Sync. Mode)

4-3-1 Line timing

*1 The highest Scanning rate is 23usec (= the shortest
period of scanning). The time is common for the products.
*2 The highest Scanning rate is depended on Output
mode ( Camera Link® Output Configuration) .
Example
1) set External Sync. mode
SS 01 CR
2) Set internal Sync. Mode and Line period
SS 00 (data) (data) (data) (data) CR
TM-XG537C
【 External Sync. mode 】
Initial synchronous mode is set on the External Sync.
1) The trigger (Sync.) signal is necessary for CIS to scan
images on the external sync. mode .
2) The trigger (Sync.) signal , RDSYNC through CC1 line
of Camera Link® Interface is input to the Master port
(D1) of CIS .
3) The scanning sequence is synchronized with falling-
trigger (Sync.) signal , RDSYNC .
"L" level period of RDSYNC needs to be 0.2usec min.
at least .
4) It will be able to synchronize Image scanning function
with Conveyer system by inputting Sync. Signal
generated from Encoder circuit of conveyer system to a
Frame Gabber Board through CC1 signal line
【 Remarks 】
1) Keep the line period longer than designated one. In the
case of shorter line period , Scanning image will be not
correct .
2) Image data in Min. 10 lines after starting to input regular
sync. Signal are not valid .
Camera Link® is a registered trademark of AIA(Automated Imaging Association)