CONTROLS AND INDICATORS

F R O N T P A N E L
©
CH1 Y POSITION Control
Rotation adjusts vertical position of C H 1 w a v e f o r m on
the screen. In X - Y operation, rotation adjusts vertical
position of display.
©
CH1 VOLTS/DIV Control
Vertical attenuator for channel 1 . Provides step adjust-
ment of vertical sensitivity in 1-2-5 sequence. V A R I -
A B L E control
is turned to the C A L position,
calibrated vertical sensitivity is obtained. In X - Y opera-
tion, this control serves as the attenuator for Y - a x i s .
©
CH1 VARIABLE Control
Rotation provides fine control of channel 1 vertical sen-
sitivity. In the fully clockwise ( C A L ) position, the verti-
cal attenuator is calibrated. In X - Y operation, this control
serves as the Y - a x i s attenuation fine adjustment.
@
CH1 AC-GND-DC Switch
This s w i t c h is the C H 1 vertical axis coupling mode
selector, for X - Y operation, the Y - a x i s coupling mode
control.
A C :
A C input coupling with blocking of any DC sig-
nal component.
GND:
Vertical amplifier is disconnected from the in-
put signal and connected to ground. T h i s mode
is useful in determining the zero reference.
D C :
DC coupling, with both the DC and A C com-
ponents of the input signal displayed on the C R T .
©
CH1 INPUT jack
Vertical input for channel 1 trace in normal s w e e p oper-
ation. Y - a x i s input for X - Y operation.
Fig. 2
(6)
$ CH2 POSITION/PULL INVert Control
• C H 2 P O S I T I O N :
Rotation adjusts vertical position of channel 2
trace.
INV:
Push-pull s w i t c h selects channel 2 signal in-
verted (PULL INV) w h e n pulled out.
(Hereafter P U L L INV is described as C H 2 INV.)
the
©
CH2 V O L T S / D I V Control
Vertical attenuator for C H 2 . Provides the same func-
tion a s V O L T S / D I V Control © for C H 1 . In X - Y opera-
tion, the control serves as the X - a x i s attenuator.
©
CH2 VARIABLE Control
Rotation provides fine control of channel 2 vertical sen-
sitivity.
Provides the same function as V A R I A B L E Control © for
C H 1 .
In X - Y operation, this control serves for X - a x i s at-
tenuation fine adjustment.
©
C H 2 AC-GND-DC Switch
Three-position lever s w i t c h which operates as follows:
A C :
Blocks DC component of channel 2 input signal.
GND:
Opens signal path and grounds input to vertical
amplifier. This provides a zero-signal base line,
the position of w h i c h can be used a s a reference
w h e n performing D C measurements.
DC:
Direct input of A C and DC component of chan-
nel 2 input signal.