A C a u t i o n : R e a d t h i s p a g e c a r e f u l l y t o k e e p y o u r s a f e t y .
Be sure to d i s c o n n e c t the p o w e r cable from the s o c k e t before conducting the following operation.
R E P L A C I N G T H E
F U S E
In case the fuse has blown, locate the cause. If the fuse
itself is the c a u s e , replace it as follows:
1 . Pull the plug of the power cord from the power outlet.
2. Remove the fuse holder in the rear panel using a stan-
dard screwdriver (see Fig. 4 9 ) .
3 . T a k e out the blown f u s e , and in its place, insert a new
fuse.
4 . Set the label of your line voltage to the mark • , then
plug the fuse holder containing the new fuse into the rear
panel.
Fuse holder
Fig. 4 9
3 4
MAINTENANCE
For Electric S h o c k Protection:
C H A N G I N G T H E S U P P L Y
Remove the fuse holder in the rear panel using a standard
screwdriver. T h e n set the label of your line voltage to the
mark •
changing the supply setting from 1 0 0 / 1 2 0 V to 2 2 0 / 2 4 0 V ,
change the 1.2 A fuse for a 0 . 7 A one. (see Fig. 4 9 )
V O L T A G E
and plug the fuse holder back into place. W h e n