CS-1044
C S - 1 0 2 5
FRONT PANEL
T POSITION
0
Rotation adjusts vertical position of channel 1 trace.
In X-Y operation, rotation adjusts vertical position of
display.
®
VOLTS/DIV
Vertical attenuator for channel 1; provides step adjust-
ment of vertical sensitivity. When VARIABLE control
(3) is set t o CAL, vertical sensitivity is calibrated in 12
steps from 5 V/div t o 1 mV/div.
For X-Y operation, this control provides step adjustment
of vertical sensitivity.
(3)
VARIABLE Control
Rotation provides fine control of channel 1 vertical sen-
sitivity. In the fully clockwise (CAL) position, the ver-
tical attenuator is calibrated. For X-Y operation, this
control serves as the Y axis attenuation fine adjust-
ment.
AC-GND-DC
0
Three-position lever switch which operates as follows:
AC:
Blocks dc component of channel 1 input signal.
GND:
Opens signal path and grounds input t o vertical
CONTROLS AND INDICATORS
Fig. 2
amplifier. This provides a zero-signal base line,
the position of which can be used as a
reference when performing dc measurements.
DC:
Direct input of ac and dc component of channel
1 input signal.
(5) INPUT Jack
Vertical input for channel 1 trace. Vertical input for X-Y
operation.
©
VOLTS/DIV
Vertical attenuator for channel 2; provides step adjust-
ment of vertical sensitivity. When VARIABLE control
(7) is set t o CAL, vertical sensitivity is calibrated in 12
steps from 5 V/div to 1 mV/div.
In X-Y operation, this control provides step adjustment
of horizontal sensitivity.
(7) VARIABLE Control
Rotation provides fine control of channel 2 vertical sen-
sitivity. In the fully clockwise (CAL) position, the ver-
tical attenuator is calibrated. In X-Y operation, this con-
trol becomes the fine horizontal gain control.