LCD/LED CHECK
DIAG MENU (1/3)
Page down
5. LCD+LED
Boot Flag
:
AIN1(B/U)
:
AIN1(Main)
:
AIN0
:
Tablet
:
COM
:
Note : The display must be free from unevenness and flicker.
o: ON
u: OFF
F: Flashes
F/L: Front Light
No.
Operating procedure
1
Connect the AC adapter, supply power to the
SL-5500, and press the FULL RESET button.
2
Touch No. 5 LCD + LED.
3
Press [OK] key.
4
Press [OK] key.
5
Press [OK] key.
6
Press [OK] key.
7
Press [OK] key.
8
Press [OK] key.
9
Press [OK] key.
10
Press [OK] key.
11
Press [OK] key.
12
Press [OK] key.
13
Press [on/off] key.
Page up
V
:
- --
CF CD
:H
SD CD
:H
SD WP
:H
M.B.L
:
Version
Display
DIAG MENU (1/3)
White background
White background
White background
Gradation
Black/white one-
point check pattern
Black/white one-
point check pattern
Black background
Red background
Green background
Blue background
DIAG menu
Turns off.
SL-5500 DIAGNOSTICS AND CHECK ITEMS
LED
F/L
Orange
Green
u
u
u
DIAG is booted.
u
u
MAX
White background is displayed. F/L turns on.
u
u
u
White background is displayed. F/L turns off.
u
u
MIN
White background is displayed. F/L turns on.
u
u
2nd
Black on the lower side and white gradually
increases as it goes up.
u
u
3rd
Check pattern. F/L is rather bright.
u
u
MAX
Check pattern. F/L is rather bright.
o
u
MAX
Black background (Ignore bluish color.)
Orange LED turns on.
u
o
MAX
Red background
Green LED turns on.
o
o
MAX
Green background
Both LED's turn on.
F
F
MAX
Blue background
Both LED's flashing.
u
u
u
Enters DIAG menu.
Both LED'S/FL's turn off.
u
u
u
After the display turns off completely
– 51 –