Download Print this page

Sharp SL-5500 Service Manual page 11

Personal mobile tool
Hide thumbs Also See for SL-5500:

Advertisement

PC-UM10M
(4) PIN DESCRIPTION
48
GPIO0
49
GPIO1
GPIO2
GPIO3
N.C.
DVSS1
-RST
TOP VIEW
SSYNC
SDOUT
SCLK
SDIN
IRQ
N.N.
GPIO4
GPIO5
DVDD2
64
1
(5) PIN FUNCTION
Symbol
Pin No.
A/D/P
I/O
SCLK
58
D
SSYNC
56
D
SDIN
59
D
SDOUT
57
D
IRQ
60
D
RST
55
D
TSPX
45
A
I/O
TSMX
43
A
I/O
TSPY
42
A
I/O
TSMY
44
A
I/O
AIN0
40
A
AIN1
39
A
AIN2
38
A
AIN3
37
A
ADSYNC
5
D
EXRINT
47
A
TELOP
28
A
TELON
29
A
TELIP
33
A
TELIN
34
A
VBO1P
12
A
VBO1N
13
A
33
32
AVDD4
N.C.
AVSS3
TELON
TELOP
AVDD3
N.C.
VREF
MICBIAS
AVSS2
VBIN2N
VBIN2P
VBIN1N
VBIN1P
AVDD2
17
N.C.
16
DEF
Group
I
HOST
Serial data transfer clock. Serial data is transferred synchronizing with this clock.
SCLK is used as the master clock for TC35143AF. The specification of SCLK is 9.216 MHz,
with duty ratio 50%. Connect to the clock output of SIB master chip.
I
HOST
This signal provides synchronization for serial data frames. 72kHz clock. 1 frame consists
of 128 bits of serial data. Connect to the synchronizing signal output of SIB master chip.
I
HOST
Serial input data terminal. Serial data input through the SDIN terminal is latched inside at
the falling edge of SCLK. Connect to the data output of SIB master chip.
O
HZ
HOST
Serial output data terminal. Serial data output through SDOUT terminal is output, synchro-
nizing with the rising edge of SCLK. Connect to the data input of SIB masterchip.
O
L
HOST
Interrupt output terminal. Interrupt factors output from the control resistor to this terminal
are set. The signal level at the time of interrupt is active high.
I
HOST
System reset. This signal is active low.
HZ(IN)
TSC
Interface terminal for touch screen X plate. Open when not in use.
HZ(IN)
TSC
Interface terminal for touch screen X place. Open when not in use.
HZ(IN)
TSC
Interface terminal for touch screen Y plate. Open when not in use.
HZ(IN)
TSC
Interface terminal for touch screen Y plate. Open when not in use.
I
ADC
ADC input
I
ADC
ADC input
I
ADC
ADC input
I
ADC
ADC input
I
ADC
Synchronizing clock input terminal when putting 10-bit ADC in the external clock synchro-
nizing mode. ADC starts conversion synchronizing with the edge of ADSYNC.Pull down
when not in use.
I
TSC
Terminal to which external resistance is connected, for adjusting detection sensitivity in
touch detection mode. Connect a resistance of more than 16kΩ between AVDD5.
O
HZ
TEL
Positive polarity output terminal for telephone line CODEC
O
HZ
TEL
Negative polarity output terminal for telephone line CODEC
I
TEL
Positive polarity input terminal for telephone line CODEC. Open when not in use.
I
TEL
Negative polarity input terminal for telephone line CODEC. Open when not in use.
O
HZ
VB
Positive polarity output terminal 1 for sound CODEC. It is used for the handset speaker.
O
HZ
VB
Negative polarity output terminal 1 for sound CODEC. It is used for the handset speaker.