1. Affix the LPF, CCD Rubber, and CCD Board (in that order) to the Lens 
Unit, and secure using 2 Screws.
Caution 1:
Before assembling, remove dust from the inside of the lens as shown.
Caution 2:
Line up the top and bottom of the Lens Unit and CCD Board as shown.
Caution 3:
Insert the locating pins of the Lens Unit into the locating holes of the 
CCD Board as shown.
Caution 4:
The CCD Rubber can be affixed in any direction. LPF is no inside and 
outside.
Caution 5:
Inspect the LPF and the surface of the CCD glass with a magnifying 
glass, and remove any dust before assembling.
Caution 6:
After assembling, lightly shake the Lens Unit. If you hear no rattling, 
the parts have been assembled securely.
11. ADJUSTMENTS
11.1. TOOLS AND EQUIPMENT FOR ADJUSTMENT AND REPAIR
(1) HP light box
- Light Box [with Standard Accessories]: VFK1164TDVLB
- Lamp [for Light Box]: VFK1164LA02
- Color Chart: VFK1164TDVCB
- Color Temp. Conversion Filter for 5100K: VFK1164LBB12
- ND Filter: VFK1164ND06
- Collimator (Infinity Adjustment Lens)[with Focus Pattern Chart]: 