BASIC OPERATION
Parameter Name
1007
Clock (month, day)
1008
Clock (hour, minute)
Integral stop selection
1015
at limited frequency
PTC thermistor
1016
protection detection
time
Monitor with sign
1018
selection
Trace operation
1020
selection
1021
Trace mode selection
1022
Sampling cycle
Number of analog
1023
channels
1024
Sampling auto start
Trigger mode
1025
selection
Number of sampling
1026
before trigger
Analog source
1027
selection (1ch)
Analog source
1028
selection (2ch)
Analog source
1029
selection (3ch)
Analog source
1030
selection (4ch)
Analog source
1031
selection (5ch)
Analog source
1032
selection (6ch)
Analog source
1033
selection (7ch)
Analog source
1034
selection (8ch)
Analog trigger
1035
channel
34
Setting range
Initial value
101 to 131,
201 to 229,
301 to 331,
401 to 430,
501 to 531,
601 to 630,
101
701 to 731,
801 to 831,
901 to 930,
1001 to 1031,
1101 to 1130,
1201 to 1231
0 to 59,
100 to 159,
200 to 259,
300 to 359,
400 to 459,
500 to 559,
600 to 659,
700 to 759,
800 to 859,
900 to 959,
1000 to 1059,
1100 to 1159,
0
1200 to 1259,
1300 to 1359,
1400 to 1459,
1500 to 1559,
1600 to 1659,
1700 to 1759,
1800 to 1859,
1900 to 1959,
2000 to 2059,
2100 to 2159,
2200 to 2259,
2300 to 2359
0
0 to 2, 10 to 12
0 to 60 s
0 s
9999
0, 9999
0
0 to 4
0
0 to 2
2
0 to 9
4
1 to 8
0
0, 1
0
0 to 4
90%
0 to 100%
201
202
1 to 3, 5 to 14,
17 to 20,
203
22 to 24,
32 to 36,
39 to 42,
204
52 to 54, 61, 62,
64, 67, 71 to 75,
205
87 to 98,
201 to 213,
222 to 227,
206
230 to232,
235 to 238
207
208
1
1 to 8
Parameter Name
Analog trigger
1036
operation selection
1037
Analog trigger level
Digital source
1038
selection (1ch)
Digital source
1039
selection (2ch)
Digital source
1040
selection (3ch)
Digital source
1041
selection (4ch)
Digital source
1042
selection (5ch)
Digital source
1043
selection (6ch)
Digital source
1044
selection (7ch)
Digital source
1045
selection (8ch)
1046
Digital trigger channel
Digital trigger
1047
operation selection
Display-off waiting
1048
time
1049
USB host reset
DC brake judgment
1072
time for anti-sway
control operation
Anti-sway control
1073
operation selection
Anti-sway control
1074
frequency
Anti-sway control
1075
depth
Anti-sway control
1076
width
1077
Rope length
1078
Trolley weight
1079
Load weight
Deceleration time at
1103
emergency stop
1106
Torque monitor filter
Running speed
1107
monitor filter
Excitation current
1108
monitor filter
Speed limit method
1113
selection
Torque command
1114
reverse selection
Speed control integral
1115
term clear time
Constant output range
1116
speed control P gain
compensation
Speed control P gain 1
1117
(per-unit system)
Speed control P gain 2
1118
(per-unit system)
Model speed control
1119
gain (per-unit system)
Per-unit speed control
1121
reference frequency
Setting range
Initial value
0
0, 1
1000
600 to 1400
1
2
3
4
1 to 255
5
6
7
8
1
1 to 8
0
0, 1
0 min
0 to 60 min
0, 1
0
3 s
0 to 10 s
0, 1
0
1 Hz
0.05 to 3 Hz, 9999
0
0 to 3
0
0 to 3
1 m
0.1 to 50 m
1 to 50000 kg
1 kg
1 kg
1 to 50000 kg
5 s
0 to 3600 s
9999
0 to 5 s, 9999
0 to 5 s, 9999
9999
9999
0 to 5 s, 9999
9999
0 to 2, 10, 9999
1
0, 1
0 s
0 to 9998 ms
0%
0 to 100%
9999
0 to 300, 9999
9999
0 to 300, 9999
0 to 300, 9999
9999
60 Hz
0 to 400 Hz

Advertisement

loading

This manual is also suitable for:

Fr-a800-eFr-a870-02300-eFr-a870-02860-e