Parameter Name
Seventh target
*4
478
position upper 4 digits
Eighth target position
*4
479
lower 4 digits
Eighth target position
*4
480
upper 4 digits
Ninth target position
*4
481
lower 4 digits
Ninth target position
*4
482
upper 4 digits
Tenth target position
*4
483
lower 4 digits
Tenth target position
*4
484
upper 4 digits
Eleventh target
*4
485
position lower 4 digits
Eleventh target
*4
486
position upper 4 digits
Twelfth target position
*4
487
lower 4 digits
Twelfth target position
*4
488
upper 4 digits
Thirteenth target
*4
489
position lower 4 digits
Thirteenth target
*4
490
position upper 4 digits
Fourteenth target
*4
491
position lower 4 digits
Fourteenth target
*4
492
position upper 4 digits
Fifteenth target
*4
493
position lower 4 digits
Fifteenth target
*4
494
position upper 4 digits
Remote output
495
selection
496
Remote output data 1
497
Remote output data 2
PLC function flash
498
memory clear
Communication error
*6
500
execution waiting time
Communication error
*6
occurrence count
501
display
Stop mode selection at
502
communication error
503
Maintenance timer 1
Maintenance timer 1
504
alarm output set time
Speed setting
505
reference
S-pattern time at a
516
start of acceleration
S-pattern time at a
517
completion of
acceleration
S-pattern time at a
518
start of deceleration
*1
Differs according to types. (FM type/CA type)
*4
The setting is available when a vector control compatible option is installed. For the corresponding parameters of each option, refer to the
Instruction Manual of the option.
*6
The parameter is available when a communication option is installed.
Setting range
Initial value
0
0
0
0
0
0
0
0
0
0 to 9999
0
0
0
0
0
0
0
0
0
0, 1, 10, 11
0
0 to 4095
0 to 4095
0
0, 9696
0
(0 to 9999)
0 s
0 to 999.8 s
0
0
0
0 to 4, 11, 12
0
0 (1 to 9998)
9999
0 to 9998, 9999
*1
1 to 590 Hz
60/50 Hz
0.1 s
0.1 to 2.5 s
0.1 s
0.1 to 2.5 s
0.1 to 2.5 s
0.1 s
Parameter Name
S-pattern time at a
519
completion of
deceleration
522
Output stop frequency
Modbus®-RTU
539
communication check
time interval
USB communication
547
station number
USB communication
548
check time interval
549
Protocol selection
NET mode operation
550
command source
selection
PU mode operation
551
command source
selection
552
Frequency jump range
553
PID deviation limit
PID signal operation
554
selection
555
Current average time
556
Data output mask time
Current average value
557
monitor signal output
reference current
Second frequency
560
search gain
PTC thermistor
561
protection level
Energization time
563
carrying-over times
Operating time
564
carrying-over times
Second motor
565
excitation current
break point
Second motor
566
excitation current low-
speed scaling factor
Second motor speed
569
control gain
570
Multiple rating setting
571
Holding time at a start
4 mA input check
573
selection
Second motor online
574
auto tuning
Output interruption
575
detection time
Output interruption
576
detection level
Output interruption
577
release level
Traverse function
592
selection
Maximum amplitude
593
amount
BASIC OPERATION
Setting range
Initial value
0.1 s
0.1 to 2.5 s
9999
0 to 590 Hz, 9999
9999
0 to 999.8 s, 9999
0 to 31
0
9999
0 to 999.8 s, 9999
0
0, 1
0, 1, 9999
9999
9999
1 to 3, 9999
9999
0 to 30 Hz, 9999
9999
0 to 100%, 9999
0
0 to 3, 10 to 13
1 s
0.1 to 1.0 s
0 s
0 to 20 s
Inverter
rated
0 to 3600 A
current
9999
0 to 32767, 9999
0.5 to 30 k ,
9999
9999
0
(0 to 65535)
0
(0 to 65535)
0 to 400 Hz, 9999
9999
9999
0 to 300%
9999
0 to 200%, 9999
2
0, 2
9999
0 to 10 s, 9999
9999
1 to 4, 9999
0
0 to 2
1 s
0 to 3600 s, 9999
0 Hz
0 to 590 Hz
1000%
900 to 1100%
0
0 to 2
0 to 25%
10%
29