2.5.3 Safety stop function operation
Internal
Input power
safety circuit
status
OFF
Normal
Normal
Normal
Normal
ON
Fault
Fault
Fault
Fault
*1
ON: The transistor is conducted. OFF: The transistor is not conducted.
*2
When not using the safety stop function, short across terminals S1 and PC, S2 and PC, and SIC and SD to use the inverter. (In the initial status,
terminals S1 and PC, S2 and PC, and SIC and SD are respectively shorted with shorting wires.)
*3
If any of the protective functions shown in the following table is activated, terminal So (SO) turns OFF.
Error definition
Option fault
Communication option fault
Parameter storage device fault
Retry count excess
Parameter storage device fault
Operation panel power supply short
circuit
24 V DC power fault
Safety circuit fault
Overspeed occurrence
*4
If the internal safety circuit is operated normally, terminal So (SO) remains ON until E.SAF is displayed, and terminal So (SO) turns OFF when
E.SAF is displayed.
*5
SA is displayed when terminals S1 and S2 are identified as OFF due to the internal safety circuit failure.
*6
If another fault occurs at the same time as E.SAF, the other fault can be displayed.
*7
If another warning occurs at the same time as SA, the other warning can be displayed.
*8
The ON/OFF state of the output signal is the one for the positive logic. The ON and OFF are reversed for the negative logic.
*9
For SAFE signal, refer to the following table and assign the function by Pr. 190 to Pr. 196 (output terminal function selection).
Output signal
Positive logic
SAFE
*10
The use of SAFE signal has not been certified for compliance with safety standards.
For more details, refer to the Safety Stop Function Instruction Manual. Find a PDF copy of this manual in the CD-ROM enclosed
with the product.
Output
*1, *2
Input terminal
terminal
S1
S2
So (SO)
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
Operation panel
indication
E.OPT
E.OP1 to E.OP3
E.PE
E.RET
E.PE2
E.CTE
E.P24
E.SAF
E.OS
Pr. 190 to Pr. 196 settings
Negative logic
80
180
Output
signal
Inverter operation
*8, *9, *10
enable signal
SAFE
Output shutoff
OFF
OFF
(Safe state)
*3
OFF
Drive enabled
ON
Output shutoff
*4
*4
OFF
(Safe state)
Output shutoff
*4
*4
OFF
(Safe state)
Output shutoff
*3
*3
ON
ON
(Safe state)
Output shutoff
OFF
OFF
(Safe state)
Output shutoff
OFF
OFF
(Safe state)
Output shutoff
OFF
OFF
(Safe state)
Output shutoff
OFF
OFF
(Safe state)
Error definition
Speed deviation excess detection
Signal loss detection
Excessive position fault
Brake sequence fault
Encoder phase fault
CPU fault
Internal circuit fault
WIRING
Operation panel indication
*6
*7
E.SAF
SA
Not displayed
Not displayed
Not displayed
Not displayed
Displayed
Displayed
Displayed
Displayed
Not displayed
Displayed
*5
Displayed
Not displayed
Displayed
Displayed
Displayed
Displayed
Displayed
Displayed
Operation panel
indication
E.OSD
E.ECT
E.OD
E.MB1 to E.MB7
E.EP
E.CPU
E.5 to E.7
E.13
17