Figure 96. System fan installation
Step 1.
Press the fan cage bracket to the front of the server.
Step 2.
Position the system fan so that the airflow arrow on the fan points toward the rear of the server, and
insert the fan into the bracket. Ensure that the fan is fully seated in its slot in the fan bracket.
Note: The correct airflow is from the front to the rear of the server.
Step 3.
Connect the fan cable to the system board.
Complete the parts replacement. See "Complete the parts replacement" on page 164.
System fan cage replacement
Use this information to remove and install the system fan cage.
Remove the system fan cage
Use this information to remove the system fan cage.
"Read the
installation
Guidelines" on
page 53
ThinkSystem SR550 Maintenance Manual
122
"Power off
the server
for this task"
on page 13
"ATTENTION:
Static Sensitive Device
Ground package before opening"
on page 56