can improve the system damping and eliminate oscillations through adjusting F4.12
F4.13.Generally do not need to adjust.
Code
F4.14
F4.15
When separating V/F operatesÿ the output voltage will set by the user.If F4.14 set to
1(keyboard set),setting the size of the output voltage instruction by F4.15,no more than
motor rated voltage and output voltage of bus bar can provide|(The maximum output
voltage of the bus can provide is
as Analog value, input pulse, communication.100% is Corresponding to the motor rated
voltage value.
Code
F4.16
F4.17
Separating V/F output voltage generated by the voltage instruction through the up
(down) slope.F4.16 set the up and speed of the slope,F4.17 set the down and speed of
the slope.Voltage rising (falling) time is equal to the output voltage from 0 up (down) to the
time required to 100.0%.

6.6 F5 Group: Input terminals

Code
F5.00
This parameter defines four different control modes that control the inverter operation
through external terminals.
Name
Voltage separation control
Keypad setting voltage
V
/ 2
bus
).Voltage command also set by the way,such
Name
Voltage rising time
Voltage falling time
Name
Terminal control mode
81
Setting Range
0ÿ^60 00
0~440V0 0V0
Setting Range
0.1ÿ^3600.0S0 1.0S0
0.1ÿ^3600.0S0 1.0S0
Setting Range
0ÿ^30 00