The torque is set using the high speed pulse HDI. 0 to F5.23 correspond to 0 to
F3.10.
6: Multi-speed setting torque
Set the torque using multi-speed. 100% corresponds to 0 to F3.10.
7: Communication set torque
Use communication to set the torque. Via MODBUS.
Code
F3.12
When F3.11 is set to 0, the torque is set by this parameter.
Code
F3.13
This parameter is the low speed torque boost value for torque control.
Code
F3.14
F3.15
The above two parameters are used for occasions where the bus voltage fluctuates
greatly, suppressing the rapid rise of the bus voltage and reducing the overvoltage alarm.
Code
F3.16
F3.17
Keyboard setting torque
Low speed torque boost during torque
control
Name
Overvoltage PID proportional gain (Kp)
Overvoltage PID integration time
Name
VC controls the weak magnetic
coefficient
VF control weak magnetic coefficient 20.0ÿ^300.0%0 200.0%0
Name
Name
76
Setting Range
0.0%ÿ^200.0%
0 50.0%0
Setting Range
0.0%ÿ^20.0%0 5.0%0
Setting Range
0.01ÿ^10.000 0.200
0.00ÿ^100.00S0 0.10S0
Setting Range
20.0ÿ^300.0%0 100.0%0