0x73: Steamer NTC Error

0x73
NTC2 failure or Wiring defective or Main Board defective.
Checks to perform:
Measure the resistance value
of NTC3 between terminals of
J8-1 and J8-2 Wiring Connector.
Is the resistance value between
4.9 KΩ to 6.5 KΩ at 20 ° to 25 °C?
(See Fig. 147)
Y
E
S
Is wiring between Main Board and NTC3
connected properly?
Y
E
S
Replace the Main Board and repeat the diagnostic
cycle to check for any further errors.
Fig. 147: Resistance Measurement on J8 8-Pin
Connector
Troubleshooting Based on Error Codes
Detach the connector and measure
directly on the NTC2 terminal. Is the
NO
resistance value between 49 kΩ
to 63.7 KΩ at 20 ° to 25 °C? (See
Fig. 148)
Check / Replace the wiring and repeat the diagnostic
Check / Replace the wiring and repeat the diagnostic
NO
53
WARNING
Check that all the connectors are correctly
inserted.
NO
Y
E
S
cycle to check for any further errors.
cycle to check for any further errors.
Fig. 148: Resistance Measurement on NTC3
0x73
Replace the NTC3 and
repeat the diagnostic
cycle to check for any
further errors.