7.3.3

Instruction codes

 Instruction code definition
Set the instruction code using a remote register (RWw) (refer to
The definition read by the instruction code is stored in the remote register (RWr) (refer to
Item
Operation mode
Output
frequency
,


Output current
Monitor
Output voltage
Special monitor
Special monitor
selection No.
Read/
Code
write
number
H0000: Network operation mode
H0001: External operation mode, External JOG operation mode
Read
H7B
H0002: PU operation mode, External/PU combined operation modes 1 and 2,
PUJOG operation mode
H0000: Network operation mode
Write
HFB
H0001: External operation mode
H0002: PU operation mode (Pr.79 = "6", Pr.340 = "10 or 12")
H0000 to HFFFF:
Read
H6F
Running frequency: 0.01 Hz increments
Speed (machine speed): 1 increments
H0000 to HFFFF:
Read
H70
Output current (hexadecimal): Increments 0.01 A/0.1 A
H0000 to HFFFF:
Read
H71
Output voltage (hexadecimal): Increments 0.1 V
Read
H72
H0000 to HFFFF: Check the data of the monitor selected by the instruction code HF3.
Read
H73
H01 to HFF: Selection of the monitored item (monitor code) (Refer to
If a monitor code out of the range is set, a range error occurs.
Write
HF3

page