Download Print this page

Hardware Description - ABB REC670 Product Manual

Relion 670 series, pre-configured
Hide thumbs Also See for REC670:

Advertisement

ABB
Bay control REC670
Pre-configured
Product version: 1.1
situated at distances <110 km or from the
IED to optical to electrical converter with G.
703 or G.703E1 interface located on a
distances <3 km away. The LDCM module
sends and receives data, to and from another
LDCM module. The IEEE/ANSI C37.94
standard format is used.
Galvanic interface G.703 resp G.703E1
The external galvanic data communication
converter G.703/G.703E1 makes an optical-to-
galvanic conversion for connection to a
multiplexer. These units are designed for 64
kbit/s resp 2Mbit/s operation. The converter
is delivered with 19" rack mounting
accessories.

5. Hardware description

Hardware modules
Power supply module PSM
The power supply module is used to provide
the correct internal voltages and full isolation
between the terminal and the battery system.
An internal fail alarm output is available.
Binary input module BIM
The binary input module has 16 optically
isolated inputs and is available in two
versions, one standard and one with
enhanced pulse counting capabilities on the
inputs to be used with the pulse counter
function. The binary inputs are freely
programmable and can be used for the input
of logical signals to any of the functions.
They can also be included in the disturbance
recording and event-recording functions. This
enables extensive monitoring and evaluation
of operation of the IED and for all associated
electrical circuits.
1MRK 511 192-BEN B
Binary output module BOM
The binary output module has 24
independent output relays and is used for
trip output or any signaling purpose.
Static binary output module SOM
The static binary output module has six fast
static outputs and six change over output
relays for use in applications with high speed
requirements.
Binary input/output module (IOM)
The binary input/output module is used
when only a few input and output channels
are needed. The ten standard output channels
are used for trip output or any signalling
purpose. The two high speed signal output
channels are used for applications where
short operating time is essential. Eight
optically isolated binary inputs cater for
required binary input information.
mA input module MIM
The milli-ampere input module is used to
interface transducer signals in the –20 to +20
mA range from for example OLTC position,
temperature or pressure transducers. The
module has six independent, galvanically
separated channels.
Optical ethernet module OEM
The optical fast-ethernet module is used to
connect an IED to the communication buses
(like the station bus) that use the IEC
61850-8-1 protocol (port A, B). The module
has one or two optical ports with ST
connectors.
Serial SPA/IEC 60870-5-103 and LON
communication module SLM
The optical serial channel and LON channel
module is used to connect an IED to the
communication that use SPA, LON, or
IEC60870–5–103. The module has two optical
ports for plastic/plastic, plastic/glass, or glass/
glass. One port is used for SPA and IEC
60870-5-103 one port is used for LON.
Issued: June 2010
19

Advertisement

loading