2. Wi-Fi Connection: "MSP Not Found"
If the OmniLogic system has not been configured, web registration will not be
successful. If not configured, load a backed-up file or complete the configuration
process before continuing.
Verify the Firmware is up-to-date
Verify MSP is Configured
Step 2A
Step 2B
Locate the 'config' icon & go to system info. Verify the
When configured, system dashboard will appear (as
MSP rev. matches the latest found at
shown above). When not configured, the Config. Icon
www.hayward.com
Support Center> Automation >
will default in the center of the screen. IF configured,
OmniLogic > Firmware Updates. IF correct, go to step
go to step 2C. IF the configuration is not present,
1B. IF NOT, contacting a pool professional is advised*,
contact a pool professional*. Web registration requires
updates to firmware may resolve the problem.
a configuration to be present.
*Go to the following address to locate a pool professional:
https://www.hayward-pool.com/shop/en/pools/Dealer-Locator
24
Need help?
Do you have a question about the OmniLogic and is the answer not in the manual?
Questions and answers
CHLOR Relay K1 and K2 Stuck Closed Chlorinator alarm
To fix the CHLOR Relay K1 and K2 stuck closed alarm on a Hayward OmniLogic system, try the following steps:
1. Power Cycle the System – Turn off the OmniLogic system, wait a few minutes, then turn it back on to see if the error clears.
2. Check for Physical Relay Issues – Inspect the relays for any visible damage or signs of burning.
3. Replace the 4A Fuse – If the error is intermittent, replacing the 4A fuse may help resolve the issue.
4. Update Firmware – Ensure the OmniLogic system is running the latest firmware, as updates may fix known issues.
5. Inspect Wiring and Connections – Verify that all wiring connections to the relays and T-Cell current sensor are secure and properly connected.
6. Monitor Error Behavior – If the error disappears and returns intermittently, it could indicate a failing relay that may need replacement.
If the issue persists after these steps, consider contacting Hayward support for further troubleshooting or relay replacement.
This answer is automatically generated