Bosch Rexroth lndraControl VPB 40.1 Project Planning Manual page 45

Control cabinet pc
Table of Contents

Advertisement

DOK-SUPPL*-VPB*40.1***-PR02-EN-P
Rexroth IndraControl VPB 40.1 Control Cabinet PC
CAUTION
Use an isolating transformer to generate the AC230/115 V, see
230 V voltage connection via isolating transformer" on page
The AC 230/115 V connection occurs via a 3-pin inlet connector for AC con‐
nectors on the connector panel. The maximum line cross-section for the con‐
nected lines is 1.5 mm
.
2
PE
PE
Fig.7-24:
AC 230/115 V connection, X20, pin connection
Parameter
Rated voltage
Current consumption for U
N
Current consumption for U
N
Inrush current for U
= AC 230 V
N
Inrush current for U
= AC 115 V
N
Input fuse
Fig.7-25:
Technical data AC 230/115 V connection
Bosch Rexroth AG
The supply voltage must comply with overvolt‐
age category II! Otherwise the integrated pow‐
er supply unit might be destroyed.
X20
PE
Value
AC 85 V... AC 264 V
auto range
= AC 230 V
0.7 A
= AC 115 V
1.4 A
30 A cold start 25 °C
15 A cold start 25 °C
1.6 A (5×20)
43/81
Connections
fig. 7-26 "AC
44.
Belegung
Assignment
N1
U2

Advertisement

Table of Contents
loading

Table of Contents