Management Interfaces; Environment Parameters; Storage Temperature; Operating Temperature - Huawei AR500 Series Manual

Hide thumbs Also See for AR500 Series:
Table of Contents

Advertisement

Huawei
AR500&AR510&AR531&AR550&1500&AR2500
Industrial Switch Routers
Hardware Description
Item
Rated input voltage
(DC)
Maximum input
voltage (DC)
RPS power supply
PoE power supply
Power consumption
Maximum power
consumption
Heat dissipation
Fans
Airflow (facing the
front panel)
Interface density
Management
interfaces
Console interface
USB 2.0 interfaces
Service interfaces
Extended slots

Environment parameters

Operating
temperature
Storage
temperature
Operating relative
humidity
Operating altitude
Issue 10 (2019-03-06)

Specification

100 V to 110 V
110 V
Not supported
Supported on GE electrical interfaces GE0 to GE3, with a maximum
of 30 W power on each interface
65 W
None
None
1 (M12)
1 (MicroUSB)
1
WAN interfaces: eight LTE antenna interfaces
LAN interfaces: two Wi-Fi antenna interfaces and four GE electrical
interfaces
Multimedia service interface: One GPS/BDS antenna interface
Not supported
-10°C to +70°C (14°F to 158°F) (PoE not enabled)
-10°C to +60°C (14°F to 140°F) (PoE enabled)
NOTE
When the altitude is 1800 m-5000 m (5906ft.-16404.2 ft.), the highest
operating temperature reduces by 1°C (1.8°F) every time the altitude increases
by 220 m (722 ft.).
-40°C to +85°C (-40°F to +185°F)
5% to 95%, noncondensing
< 5000 m (16404.2 ft.)
Copyright © Huawei Technologies Co., Ltd.

3 Chassis

224

Hide quick links:

Advertisement

Table of Contents
loading