KX-MB2061CXB/KX-MB2061CX2/KX-MB2062CXB
6.11.3.3. FAN stop
When IC300_pinA11 is "L", both Q512 and Q510 are turned off, then both FAN stop.
6.11.3.4. Rotation detect signal
During the FAN rotation, the pulse signal is output from pin 2 of FAN motors as the rotation detects signals.
If the period of the pulse is wider than predetermined value, it is judged that FAN error occurred.
Then display shows "Call Service 4". (Refer to CALL SERVICE 4 (P.153)).
6.11.4. Control table
FANON1H
FAN1and FAN2 mode
(IC300_pinA11)
H
Full speed
Pulse
Half speed
L
Stop
6.11.5. Waveform
55