KX-MB2061CXB/KX-MB2061CX2/KX-MB2062CXB
12.3.27.3. Broken Parts Repair Details
(D1)
If D1 is short-circuit, F2 will melt (open).
In this case, replace all of the parts (D1, F2).
(C5)
If overvoltage (Approx. 450V) was supplied for a power supply unit, C5 will be broken.
(Q1)
If Q1 is short-circuit, F2 will melt (open).
In this case, replace all of the parts (F2, Q1,D1).
(F101)
If F101 is melted (open), check the 24 Voltage line of the Main Board and others.
235