Panasonic KX-MB2061CXB Service Manual page 124

Multi-function printer
Hide thumbs Also See for KX-MB2061CXB:
Table of Contents

Advertisement

KX-MB2061CXB/KX-MB2061CX2/KX-MB2062CXB
Code
Function
591
FAX auto redial time disconnection
time set
592
CNG transmit select
593
Time between CED and 300bps
594
Overseas DIS detection select
595
Receive error limit value set
596
Transmit level set
598
Receiving sensitivity
599
ECM frame size
628
H.V.P.S. check
639
LSU test
655
Cause Distinction Code of Call Service 3
677
FAN test
710
Memory clear except History data
717
Transmit speed select
718
Receive speed select
722
Redial tone detect
731
CPC mode
763
CNG detect time for friendly reception 1:10 sec
774
Receiving T4 timer
775
Transmission T4 timer
784
Voice prompt test
815
Sensor check
852
Print test pattern
853
Top margin
854
Left margin
874
DTMF ON time
875
DTMF OFF time
880
History list
881
Journal 2 list
882
Journal 3 list
956
CORDLESS TEST MODE
Set Value
Effective
Range
X second
001~999
185
1:OFF
1~3
2
2:ALL
3:AUTO
1:75 msec
1~3
1
2:500 msec
3:1 sec
1:detects
at
1, 2
1
the 1st time
2:detects
at
the 2nd time
1: 5%
1~4
2
2: 10%
3: 15%
4: 20%
X dBm
- 15~00
10
43= -43 dBm
20~48
48
1:256 2:64
1, 2
1
1:14400BPS
1~6
1
2:12000BPS
3:9600BPS
4:7200BPS
5:4800BPS
6:2400BPS
1:14400BPS
1~6
1
2:12000BPS
3:9600BPS
4:7200BPS
5:4800BPS
6:2400BPS
1:ON 2:OFF
1, 2
1
X 10 msec
000~255
033
1~3
3
2:20 sec
3:30 sec
X 100 msec
00~99
00
X 100m sec
00~99
00
X 0.5mm
01~11
X 0.5mm
01~11
X msec
060~200
100
X 10 msec
06~20
10
Command
124
Default
Sets the FAX redial interval during FAX communi-
cation.
Lets you select the CNG output during FAX trans-
mission. ALL: CNG is output at phase A. AUTO:
CNG id output only when automatic dialing is per-
formed. OFF: CNG id not output at phase A. Refer
to Sometime There Is a Transmit Problem
(P.176).
See How To Output The Journal Report (P.183)
and Receive Problem (P.177).
See How To Output The Journal Report (P.183)
and Sometime There Is a Transmit Problem
(P.176).
If the number of errors during transmission exceeds
this value, the sending side terminates the call.
Selects the FAX transmission level. Refer to Some-
time There Is a Transmit Problem (P.176) and
Receive Problem (P.177).
Used when there is an error problem. Refer to How
To Output The Journal Report (P.183).
----------
See Test Functions (P.119).
See Test Functions (P.119).
See CALL SERVICE Troubleshooting Guide
(P.149).
See Test Functions (P.119).
Refer to Memory Clear Specification (P.125).
If the code 527 is set at 1, the code 717 and 718
work.
If the code 527 is set at 1, the code 717 and 718
work.
Sets the tone detection mode after redialing.
Sets the CPC signal detection mode from the con-
verter.
Selects the CNG detection tone of friendly recep-
tion.
Use this function when delay occurs in the line and
communication.
(ex. Mobile comm) does not work well.
Use this function when delay occurs in the line and
communication.
(ex. Mobile comm) does not work well.
You can hear the voice prompt from speaker after
pressing "SET" key.
See Test Functions (P.119).
See Test Functions (P.119).
05
----------
06
----------
----------
----------
See History (Example of a printed out list)
(P.131).
See Journal 2 (P.180).
See Journal 3 (P.181).
Remarks