5.2.2 pRRU3901 Specifications

Item
Dimensions
Weight
Input voltage
Transmission port
Power consumption

5.3 Environment Requirements

Item
Operating temperature
Storage temperature
Relative humidity
Absolute humidity
Operating pressure
Protection rate
Operating environment
Storage environment
Transport environment
Anti-seismic
performance
01 (2013-11-30)
Specifications
Height (mm)
230
≤ 3 kg
AC/DC power: 100 V AC to 120 V AC; 200 V AC to 240 V AC
PoE: -36 V DC to -60 V DC
Two FE/GE electrical ports
With one RF card: ≤ 30 W
With two RF cards: ≤ 50 W
Specifications
RHUB: –5ºC to +50ºC
pRRU3901:
Installed on a wall: –5ºC to +45ºC
Installed on a ceiling: –5ºC to +40ºC
–40ºC to +70ºC
5% RH to 95% RH
3
1 g/m
to 30 g/m
70 kPa to 106 kPa
IP20
EUROPEAN ETS 300 019-1-3 Temperature-controlled
locations Class 3.2
ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weather
protected, not temperature-controlled storage locations"
ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public
transportation"
IEC 60068-2-57 (1999-11) Environmental testing – Part 2-57:
Tests – Test Ff: Vibration – Time-history method
YD5083-99: Interim Provisions for Test of Anti-seismic
Performance of Telecommunications Equipment (telecom
industry standard in the People's Republic of China)
GR63 5.4.1 zone4: NEBS
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 Technical Specifications
Width (mm)
230
3
TM
Requirements: Physical Protection
Depth (mm)
50
23