LampSite Solution
Product Description
Table 2-4 describes the RHUB3908 indicators.
Table 2-4 RHUB3908 indicators
Indicator
RUN
ALM
ACT
CPRI0/CPRI
1
GE0/1
PWR0~7
01 (2013-11-30)
Color
Green
Red
Green
Red or
green
Green
This indicator
is on
Yellow
only when the
PHS feature
is enabled.
Yellow
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Status
Description
Steady on
There is power supply, but the RHUB is
faulty.
Steady off
There is no power supply, or the RHUB is
faulty.
Blinking on for
The RHUB is functioning properly.
1s and off for 1s
Blinking on for
The RHUB is loading software,
0.125s and off
configuring data, not working, or the
for 0.125s
software is in security version.
Steady on
Alarms have been generated, and the
device must be replaced.
Steady off
No alarms have been generated.
Blinking on for
At least one alarm has been reported. The
1s and off for 1s
RHUB may have to be replaced.
Steady on
The RHUB is activated and functioning
normally.
Steady off
The RHUB is not activated.
Blinking on for
The device is under commissioning.
1s and off for 1s
Steady green
The CPRI link is functioning properly.
Steady red
An optical module has failed to transmit or
receive signals because the optical module
is faulty or the optical fiber is broken.
Blinking red on
The CPRI link is out of lock possibly
for 1s and off for
because the dual-mode clock sources are
1s (red)
not synchronous or the data rates over
CPRI ports do not match.
Steady off
The optical module is not detected or is
powered off.
Steady on
The connection is set up.
Steady off
No connection is detected.
Blinks
Data has been transmitted or received.
Steady off
No data has been transmitted or received.
Steady on
The RHUB is supplying power to the
pRRU properly.
2 Hardware Architecture
9